B12A0 Peugeot 206 is described as Oxygen Sensor Circuit No Activity Detected Bank 2 Sensor 1. This code appears when the PCM (powertrain control module, also known as ECM or engine control module in other brands) remains at or close the 0.450 set voltage point. There are two wires dedicated for each coil; one is battery feed which usually comes from the distribution center, and the other one for the coil driver circuit from the PCM. The PCM grounds or ungrounds the circuit to activate or deactivate the coil.
Possible Causes :
|
Look for rubbing, scraping, bare wires, worn spots or melted plastic connectors. Pull the connectors apart and carefully look at the terminals (the metal parts) inside the connectors. With the valve disconnected, the red voltmeter lead should be attached to the IMRC valve power wire and the black voltmeter lead connected to ground. Look at the plug wires to make sure they are not burnt or laying on the exhaust.
Diagnostic trouble code B12A0 Peugeot 206 is not difficult to diagnose and repair. Thus, it always pays to have a qualified technician to look after your vehicle should this error code arise.
Diagnosing this code requires the engine to be in good running shape, without unmetered air entering the engine. If other codes that relates to misfiring condition, lean running or air entering the engine is present, then you must first fix those error codes before B12A0 Peugeot 206.
Fortunately, B12A0 Peugeot 206 is a fairly common OBD code, meaning that it applies to all makes and models of vehicles made after 1996.